Acelerador Lineal, Unidad de Radioterapia - Varian -  Clinac 600C

Ítem 144154694

¿Eres el vendedor de este ítem? Iniciar sesión para más opciones.
Estatus: Abierto
Tipo de ítem: Sistema completo
Categoría: Oncología
Dispositivo: Acelerador Lineal, Unidad de Radioterapia
Fabricante: Varian
Modelo: Clinac 600C
Condición: Como está
Año de fabricación: 1995
Ubicación: Estados Unidos, Connecticut
Disponibilidad: Inmediato
Cantidad: 1 disponible
Precio de unidad: 35,000.00 USD
Póngase en contacto con el vendedor
Inspeccione antes de comprar
Descripción del ítem
VARIAN, 600C w/ 2002 BrainLAB M3 MLC Radiosurgery

Description: Varian 600C plus 2002 BrainLab M3 MLC
Stereotactic Radiotherapy
600C Installed June 1995

Console Software V. 5.4

TOTAL PRICE ONLY $35,000 FOR DEINSTALLED UNIT-- AN UNHEARD OF PRICE FOR A UNIT WHICH INCLUDES THE TOTAL DEINSTALATION COST &
THE COST OF ORIGINAL BASE FRAME REMOVAL WITH THE BASE FRAME INCLUDED IN SALE
--READY TO LOAD LINAC & BASE FRAME ON TRUCK along with 2002 BRAINLAB M3 MLC: Being sold w/ 2002 BrainLAB M3 stereotactic unit
Photon Energy: 6 MV
Beam Hours: <1,300
Dual jaws
ETR Couch
Unit in good working order at time of deinstallation
De-installed Base Frame [Conventional] included
Call to discuss details


SYSTEMS BROKERED have been CRATED and SHIPPED to SATISFIED CLIENTS AT CANCER CENTERS in
INDONESIA, TURKEY, BRAZIL, COLOMBIA, URUGUAY, RUSSIA, and other locations, and to therapy centers, and service companies in the US

REFERENCES AVAILABLE UPON REQUEST.

The m3 high-resolution multileaf collimator, with its fine 3mm leaves at isocenter, has revolutionized radiosurgery by introducing conformal treatments that tailor the dose to the shape of the tumor.

The m3 enables the delivery of superior homogeneous dose distributions with a steep dose gradient – an essential requirement for SRS treatments.

The leaves of the m3 are automatically placed around the target for all beam angles with the desired margin. Risk objects may be automatically protected by the leaves, with manual adjustments able to be made at any time.

Reduced irradiation of normal tissue and the homogeneous dose distribution within the PTV contributes to superior and more efficient patient care.

m3 SETUP
The detachable 'plug and treat' design of the m3 high-resolution multileaf collimator allows fast and easy slide-on attachment to almost any existing linac accessory mount, aided by the storage trolley and with the gantry at the 180° position.

Once m3 is physically mounted to the linear accelerator, the electrical and date connection is immediate.

INTEGRATED SAFETY
The m3 is the only solution fully integrated with Varian accelerators. It communicates with Varian C-Series Clinacs as if it were an internal part of the accelerator, providing superior Clinac safety interlocks, reliability and capabilities such as Dynamic Conformal Arcs and Dynamic IMRT.

Steep dose fall-off - a fundamental requirement for radiosurgery

Multileaf collimators with a leaf thickness of 10 mm are optimized for standard radiotherapy. For stereotactic treatments, a steep dose fall-off is required to protect normal tissue and, in particular, critical structures from high doses.

To accommodate a higher resolution dose delivery, new multileaf collimator designs with 5 mm thick leaves allow the delivery of fractionated stereotactic radiotherapy, but are not generally acceptable for single fraction radiosurgery where special requirements have been defined by the AAPM (1).

The steepness of the dose gradient in radiosurgery is a function of beam geometry and beam penumbra.

Care must be taken to minimize penumbra of the collimator system because the larger the beam penumbra, the shallower the dose fall-off (Figure 1).

For radiosurgery, the recommended limit for dose gradient in the beam penumbra (from 80% to 20%) is greater than or equal to 60%/3 mm (Figure 1).

Fig. 2* [See webpage link supplied for Figures]

Most commercially available multileaf collimators have a penumbra specification from 4 to 8 mm. The m3 with its 3 mm-thin leaves has an effective penumbra of less than 3 mm for all SRS field sizes and meets all SRS requirements (Figure 2).

Thus, the dose can be tailored according to the shape of the lesion, while sparing large amounts of normal healthy tissue.

*An irregular field shape formed from diagonal, straight field edges. Measured 80%, 50% and 20% isodose lines are indicated. A sinusoidal variation in the isodose lines occurs due to the stepping effect between leaf ends and is smallest where the field is formed by the 3 mm thin leaves. Tangents between the 80% and 20% isodose lines show an increasing effective penumbra with increasing leaf thickness.

REFERENCES

AAPM Report No. 54, Stereotactic Radiosurgery, Report of Task Group 42, American Institute of Physics, June 1995 Pike, Podgorsak, et. al., 'Dose distributions in radiosurgery' Medical Physics, Mar/Apr 1990 Cosgrove, et. al., 'Commissioning of a Micro Multi-leaf Collimator and Planning System for SRS.', Radiotherapy & Oncology, (50) 1999

Find your Solution: neurosurgery solutions orthopedic solutions RT/oncology solutions ent solutions spine & trauma solutions integrated OR solutions healthcare IT solutions home print send back m3 High-Resolution Multileaf Collimator
 Preguntas y respuestas referentes a este ítem 
 
PreguntaRespuesta
General: General: Estába el equipo funcionando según las especificaciones del fabricante justo antes de ser desmantelado? Esperando confirmación
General: General: El proceso de restauración fue completado por el fabricante original o su agente autorizado Esperando confirmación
General: ¿Aún está instalado el dispositivo? Esperando confirmación
General: ¿Cuál es la fecha de restauración? Esperando confirmación
General: ¿Es usted el propietario del dispositivo? Esperando confirmación
General: ¿Posee daños visuales o no visuales? Esperando confirmación
General: Fuente de alimentación - fase Esperando confirmación
General: Fuente de alimentación - voltaje Esperando confirmación
General: ¿Incluye el precio el embalaje del sistema? Esperando confirmación
General: Es este sistema/equipo completamente aprobado por la FDA (Administración de Alimentos y Drogas)? Esperando confirmación
General: Lleva éste sistema / equipo la marca CE (Comunidad Europea)? Esperando confirmación
Manuales y Documentación: Manuales y Documentación: Existen manuales de operación? Esperando confirmación
Manuales y Documentación: ¿Posee un archivo de calibración y ajuste? Esperando confirmación
Manuales y Documentación: ¿Posee un CCF - Archivo de Quejas de Consumidor? Esperando confirmación
Manuales y Documentación: ¿Posee un cuaderno de trabajo de servicio de mantenimiento? Esperando confirmación
Manuales y Documentación: ¿Hay registro de piezas reparadas? Esperando confirmación
Does M3 come with plan software? How much for M3 only?
Información de venta
Pago
Métodos de pago: Transferencia bancaria
Porcentaje del pago por adelantado: 10%
Embalaje
El ítem no está embalado
Inspección
El vendedor autoriza la inspección del ítem? Si
Disponible para ser inspeccionado desde: Inmediato
 
Toda la información concerniente al ítem presentado en esta página ha sido proporcionada por el vendedor, y MedWOW no puede garantizar su exactitud.
¿No ha encontrado el equipo médico que esta buscando? Coloque una solicitud de Oferta
¡Una “Solicitud de Ofertas” es una excelente manera de llegar a vendedores de equipos médicos de todo el mundo!
  • Complete un simple formulario, otorgando más detalles sobre el artículo que usted está buscando.
  • Reciba hasta 3 ofertas competitivas adicionales de otros vendedores que poseen el equipo que usted esta buscando en su inventario.
  • Elija la mejor y la más adecuada oferta para usted
Coloque una solicitud de Oferta >>

Ver más Acelerador Lineal, Unidad de Radioterapia equipo a la venta


Acelerador Lineal, Unidad de Radioterapia también puede ser denominado: Acelerador Lineal, Unidad de Radioterapia
Datos del vendedor
Ubicación: Estados Unidos, Connecticut
Tipo negocio: Broker
Sepa más sobre este vendedor
Reciba informe de D&B >>
Herramientas de asistencia de compra
Hacer seguimiento de este ítem